Version 1.1.0.8
|
|
---------------
|
|
Import and export of messages as xml file
|
|
|
|
|
|
Version 1.1.0.9
|
|
---------------
|
|
importing invalid xml file; avoid iTAC.OIB.Adapter crash
|
|
|
|
|
|
Version 1.2.0.0
|
|
---------------
|
|
Configuration changed
|
|
filtering for line names implemented
|
|
support for PreSetupStation added
|
|
|
|
|
|
Version 1.2.0.1
|
|
---------------
|
|
Avoid crash if OIB core is down for maintainance. automatically re-establish connection
|
|
logging improved
|
|
|
|
|
|
Version 1.2.0.2
|
|
---------------
|
|
exception handling in setupCenterNotifyReceiver optimized.
|
|
field test version
|
|
|
|
|
|
Version 1.2.0.3
|
|
---------------
|
|
xml file writing for PackagingUnitLocation and ExternalControlResult, Configuration change necessary.
|
|
<!-- the following two are for synchronous call on scanning packaging units -->
|
|
<add key="PackagingUnitLocation" value="true"/>
|
|
<add key="ExternalControlResult" value="true"/>
|
|
|
|
Version 1.3.0.0
|
|
---------------
|
|
new libs for OIB 2.5 and SC 4.2
|
|
more Exception handling, general exception handler for uncaught exceptions
|
|
new function GetNewPackagingUnit (SC requests a packaging unit from MES)
|
|
PackagingUnitConsumedReport contains additional information about locations and remaining packaging units
|
|
|
|
Version 1.3.0.1
|
|
---------------
|
|
Adapter can read DownloadData from xml file and send it to Client
|
|
added consumedComponents information in TraceabilityData
|
|
|
|
Version 1.3.0.2
|
|
---------------
|
|
always create new input and output streams to java connector (requires java equivalent)
|
|
|
|
Version 1.3.0.3
|
|
---------------
|
|
A few more Packaging Unit fields: brightness class, ..
|
|
|
|
Version 1.3.0.4
|
|
---------------
|
|
Missing monitoring endpoint does not kill process
|
|
|
|
Version 1.3.0.5
|
|
---------------
|
|
Assembly Version still remains 1.3.0.4 from now to prevent oib configuration change
|
|
additionally startup information about FileVersion, which is now 1.3.0.5
|
|
compatible with Data Interface Version 6.10.02.374
|
|
|
|
Version 1.3.0.6
|
|
---------------
|
|
New Communication structure, DataInterface tells iTAC.OIB.Adapter on startup a remote port
|
|
Every data set opens a new connection
|
|
line control receiver configured only with port (changed adapter-configuration)
|
|
compatible with Data Interface Version 6.10.02.384
|
|
|
|
Version 1.3.0.7
|
|
---------------
|
|
catch Exception on logging(was not thread safe)
|
|
printing lineControl and setupCenter endpoints on startup
|
|
|
|
Version 1.3.0.8
|
|
---------------
|
|
LineName trim()
|
|
Events from Monitoring Queue and SetupCenter Queue sent by a thread and return immediately, preventing timeouts
|
|
|
|
Version 1.3.0.9
|
|
---------------
|
|
Exception inserting values in Hashmap fixed
|
|
possibly NullPointer prevented on MaterialMovedEvent
|
|
|
|
Version 1.3.0.10
|
|
---------------
|
|
return own address as IPv4 instead of undefined
|
|
config file modified timeout-times (now 2 minutes)
|
|
|
|
Version 1.3.0.11
|
|
---------------
|
|
Capability of reading PackagingUnitConsumedReport from file (internal feature)
|
|
Capability of reading MaterialMovedReport from file (internal feature)
|
|
management of connections to DataInterface now thread safe
|
|
|
|
Version 1.3.0.12
|
|
---------------
|
|
logging events NewSetupActive and SetupChangedReport (20120424)
|
|
config changed; new setting for NewSetupActive logging (20120424)
|
|
requesting DataInterface connection synchronized (20120425)
|
|
|
|
Version 1.3.0.13
|
|
---------------
|
|
changed log level for XML-Message-Logging from INFO to DEBUG (20120523)
|
|
changed time stamp format in logging, 3 digits for fractions of seconds (20120523)
|
|
logging configuration changed, adjustable log level for console logger (20120523)
|
|
new Parameter for Logging Xml into Console(20120523)
|
|
XML-Serialization performance improved (20120523)
|
|
|
|
Version 1.3.0.14
|
|
----------------
|
|
Capability of reading StationEventcomposite from file (internal feature 20120525)
|
|
Logging StationEventComposite corrected (20123105)
|
|
|
|
// from here we have two version for OIB 2.5 and 3.0
|
|
|
|
Version 2.5.0.15 / Version 3.0.0.15
|
|
-----------------------------------
|
|
internal structural changes
|
|
|
|
Version 2.5.0.16 / Version 3.0.0.16
|
|
-----------------------------------
|
|
preparing data structure (ComponentLocation) corrected (missing location info).
|
|
SiplacePro logging modified.
|
|
|
|
Version 2.5.0.17 / Version 3.0.0.17
|
|
-----------------------------------
|
|
skips all older BoardProcessedData messages, requires new Configuration value (20120815)
|
|
<!-- maximum age for boardProcessedMessages to be processed, in 'hours:minutes:seconds' -->
|
|
<add key="BoardProcessedDataMaxAge" value="00:30:00"/>
|
|
|
|
Version 3.0.1.18
|
|
-----------------------------------
|
|
new mechanism for line changeover eventBased Mode (20121017)
|
|
skips all older Stationevents messages, optional new Configuration value (20121017)
|
|
<!-- maximum age for StationEventMessages to be processed, in 'hours:minutes:seconds' -->
|
|
<add key="StationEventMaxAge" value="00:30:00"/>
|
|
ignored if value is not configured or invalid
|
|
|
|
Version 3.0.1.19
|
|
-----------------------------------
|
|
correction in SetupCenterReceiver (20121023)
|
|
|
|
Version 3.0.1.20
|
|
-----------------------------------
|
|
check receive time in MonitoringReceiver with UTC time (StationEvent and BoardProcessed) (20121106)
|
|
|
|
Version 3.0.1.21
|
|
-----------------------------------
|
|
use stationFullPath instead of stationTypeFullPath in downloadEvent (20121127)
|
|
|
|
// latest version usable with OIB 3.0.1.x
|
|
|
|
// from here minimum required OIB Version is 3.1.0.101
|
|
|
|
Version 3.1.0.22
|
|
-----------------------------------
|
|
Initial support of OIB 3.1; OIB Client 3.0.x is no longer supported by this Adapter. (20130307)
|
|
|
|
Version 3.1.0.23
|
|
-----------------------------------
|
|
Adapter starts even if DisplayService is not available, but in this case without Traceability function. (20130821)
|
|
|
|
Version 3.1.0.24
|
|
-----------------------------------
|
|
new ASM DLL V2.1.0.1 including BoardGateKeeper (20130919)
|
|
TraceReceiver will not be created/started if configured port is 0
|
|
Display Service Receiver will not be started if configured port is 0
|
|
|
|
Version 3.1.0.25
|
|
-----------------------------------
|
|
new ASM DLL V2.1.0.2 including modified BoardGateKeeper (20131011)
|
|
Adapter starts even if DisplayService is not available/reachable (20131011)
|
|
BoardGateKeeper will not be started if configured port is 0
|
|
sligthly changed format of xml output (bool values lower case, different date format)
|
|
|
|
Version 3.1.0.26
|
|
-----------------------------------
|
|
new ASM DLL V2.1.0.3 including modified BoardGateKeeper (20131018)
|
|
sligthly changed format of xml output (bool values lower case, different date format)
|
|
read xml files for VirtualInkspotData
|
|
|
|
Version 3.1.0.26
|
|
-----------------------------------
|
|
new ASM DLL V2.1.0.11 Virtual Inkspot Handling tested (20131025)
|
|
new configuration values "OnVIHDataRejected.ShowMessage" and "OnVIHDataRejected.StationStop" (20131025)
|
|
|
|
Version 3.1.0.27
|
|
-----------------------------------
|
|
new ASM DLL V2.1.0.14 implemented (20131120)
|
|
provide a new placementRecipeName to the line, new function startPlacementRecipe (20131022)
|
|
|
|
Version 3.1.0.28
|
|
-----------------------------------
|
|
deny board when communication break whilst VirtualInkspotRequest is active(20131204)
|
|
accept BoardProcessedData messages as xml files (20131206)
|
|
|
|
Version 3.1.0.29
|
|
-----------------------------------
|
|
get ASM OIB Product Versions (20131217)
|
|
|
|
Version 3.1.0.30
|
|
-----------------------------------
|
|
new ASM DLL V2.1.0.16 (20140113)
|
|
|
|
// from here:
|
|
// minimum required OIB Version 3.2.0.135
|
|
|
|
|
|
Version 3.2.0.31
|
|
-----------------------------------
|
|
new ASM DLL V2.2.0.1 (20140114)
|
|
use ASM OIB V3.2 (20140114)
|
|
|
|
Version 3.2.0.32
|
|
-----------------------------------
|
|
use recipeFullPath in LineChangeOverEvents instead of recipeName (20140120)
|
|
correct namespace for startJobResult (20140124)
|
|
setupCenterQueue subscription corrected (find correct stations of line) (20140120)
|
|
|
|
Version 3.2.0.33
|
|
-----------------------------------
|
|
logging on connection breakdown (20140827)
|
|
new ASM DLL V2.2.1.4 (20140909)
|
|
use ASM OIB V3.2 HF3 (3.2.0.152) (20140909)
|
|
|
|
Version 3.2.0.34
|
|
-----------------------------------
|
|
new ASM DLL V2.2.1.6, DLL backward compatible with older adapter versions (20141021)
|
|
provide additional info to displayService on rejected Tracebilitydata (20141021)
|
|
|
|
Version 3.2.0.35
|
|
-----------------------------------
|
|
ignore download events from any except the configured line (20141118)
|
|
|
|
Version 3.2.0.36
|
|
-----------------------------------
|
|
skip StationEventComposite messages without stateTransitions (20150706)
|
|
|
|
Version 3.2.0.37
|
|
-----------------------------------
|
|
accept Component to be null even if designator is set in BoardData/improved logging (20150909)
|
|
|
|
Version 3.2.0.38
|
|
-----------------------------------
|
|
new internal API Version (AsmApi.dll) / ASM Release 80 (20151209)
|
|
|
|
Version 3.2.0.39
|
|
-----------------------------------
|
|
return timestamp values as UTC (like 2016-10-07T12:33:05.0000000Z instead of 2016-10-07T12:33:05.0000000) (20162110)
|
|
|
|
Version 3.2.0.40
|
|
-----------------------------------
|
|
new asm client lib 2.3.0.1 (20170215)
|
|
|
|
Version 3.2.0.41
|
|
-----------------------------------
|
|
new asm client lib 2.3.0.2
|
|
new optional config parameter to configure inkspot fiducial handling
|
|
added all optional parameters to configuration file (20170706)
|
|
use date 01.01.0001 for any date from iTAC <= 01.01.1970 in PackagingUnitControl (20180201)
|
|
|
|
Version 3.2.0.42
|
|
-----------------------------------
|
|
new asm client lib 2.3.0.3 (20180809)
|
|
|
|
|
|
Umstellung auf OIB 5.3.0.60
|
|
|
|
--Version 5x |